VO-RSD Series VO-RSD-1500-40-01 Rapid Shutdown Device VO-RSD-1500-40-01 is a 1-string, 1500V DC firefighter safety switch for one-string residential rooftop photovoltaic systems.
1 Number of strings
1500 V DC Maximum DC voltage
40 A Maximum DC current
IP66 Protection degree
01 / PRODUCT VIEW 01 / PRODUCT OVERVIEW VO-RSD-1500-40-01 photovoltaic emergency shutdown switch Designed for 1 independent PV string, this IP66 string-level switch provides automatic thermal shutdown, shutdown feedback and a defined DC isolation point for rooftop emergency response and maintenance.
02 / TECHNICAL DATA
VO-RSD-1500-40-01 technical data Use these ratings for initial selection. Confirm the final array voltage, current, control supply, interface and applicable approval documents before ordering.
Core electrical and enclosure specifications Number of strings 1
Maximum DC voltage 1500 V DC
Maximum DC current 40 A
Protection degree IP66
Operating references 1500V/26A; 1250V/32A; 1000V/40A; 800V/40A
DC connector MC4-compatible
Control supply 230 V AC nominal; 100–270 V AC operating range
Control frequency 47–63 Hz
Temperature trigger 70°C
Operating temperature -20°C to +75°C
Dimensions (L × W × H) 190 × 230 × 105 mm
Weight 1470 g
Switch standard EN 60947-3
Show all specifications (+3) Dimension drawing Request the current dimension drawing for this model.
03 / PRODUCT SELECTION Configure VO-RSD-1500-40-01 PV string count — Fixed for this model PV string count Fixed for this model
1 string
Maximum array voltage — Select the applicable design reference Maximum array voltage Select the applicable design reference
800 V DC 1000 V DC 1250 V DC 1500 V DC
Required documents — Select for project review Required documents Select for project review
Technical datasheet Dimension drawing Applicable certification evidence
04 / APPLICATIONS
Applications for VO-RSD-1500-40-01 Rooftop PV emergency shutdown Control 1 PV string from a defined firefighter safety switch enclosure.
Maintenance isolation Provide a defined string-level disconnection point for inspection, service and fault response.
Commercial PV safety Support project shutdown strategies after the required system design and market rules are confirmed.
05 / RESOURCES VO-RSD-1500-40-01 documents Request controlled documents matched to the final rating, configuration and destination market.
VO-RSD-1500-40-01 technical datasheet Request the controlled electrical ratings and order-code document. Request Document VO-RSD-1500-40-01 dimension drawing Request the controlled 190 × 230 × 105 mm enclosure drawing. Request Document VO-RSD-1500-40-01 compliance documents Request certification evidence applicable to the ordered model and target market. Request Document How many PV strings does VO-RSD-1500-40-01 support? VO-RSD-1500-40-01 is the 1-string reference in the VO-RSD 1500V firefighter safety switch series.
What is the maximum voltage of VO-RSD-1500-40-01? The listed maximum DC voltage is 1500 V. Confirm the array open-circuit voltage at the lowest design temperature.
What control supply is required? The nominal supply is 230 V AC, with a listed operating range of 100–270 V AC at 47–63 Hz.
Are certification documents included? Applicable certification evidence must be confirmed against the ordered model, configuration and destination market before project approval.
READY FOR SELECTION?
Confirm VO-RSD-1500-40-01 for your application.